- Home
- »
- Our Product Range
- »
- Chromatographic Analyzer
Chromatographic Analyzer
Clarus 680 Gas Chromatography System (Refurbished)
Minimum Order Quantity: 1 Piece
Product Brochure
| Flow rate range | Up to 400 mL per min (adjustable) |
| Carrier Gas Options | Helium Hydrogen Nitrogen |
| Operating humidity (relative) | Range: 20% to 80% RH (non-condensing) |
| Cool Down Time | Less than 4 minutes |
| Carrier Gas Pressure | 0 to 100 ps |
| Temperature Range | Ambient +5C to 450C |
| Max Heating Rate | 120C per min |
| Cool-down Time | 4 minutes from 450C to 50C |
| Program Steps | Up to 21 temperature ramps with 22 plateaus |
| Column Capacity | Up to 3 analytical |
| Pressure Range | 0-100 psi (varies by module) |
| Gas Types | Supports Helium, Hydrogen, Nitrogen, and Argon |
| Detectability | 1 pg C sec (benzene) |
Additional Information:
- Production Capacity: 20 machines
- Delivery Time: 5-10 days
- Packaging Details: packing charges extra
HPLC system for vitamins, amino acids, and food additives
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand | Waters |
| Usage/Application | Laboratory Use |
| Flow Rate Range | 0.001 - 10.000 mL/min (0.001 mL/min increments) |
| Flow Precision | <0.1% RSD |
| Flow Accuracy | +-1% or 10 uL/min |
| Maximum Operating Pressure | up to 6000 psi (400 bar) |
| Control Software: | PRE INSTALL SOFTWARE PC (depending on brand) |
| Compliance | 21 CFR Part 11, USP, ICH, FDA guidelines |
High-Performance Liquid Chromatography (HPLC) is a trusted analytical tool for quality control and research in the food, nutrition, and pharmaceutical industries. Equipped with advanced features such as quaternary gradient pumps, autosamplers, and UV/PDA detectors, this system provides high sensitivity, reproducibility, and accuracy for complex sample analysis.
Applications:
-
Vitamins: Accurate quantification of both water-soluble (B-complex, C, folic acid) and fat-soluble (A, D, E, K) vitamins in supplements and fortified foods.
-
Amino Acids: Determination of essential and non-essential amino acids in food, beverages, and biological samples (via derivatization or fluorescence detection).
-
Food Additives: Analysis of preservatives, artificial sweeteners, flavoring agents, and colorants to ensure safety and regulatory compliance.
Key Features:
-
Wide detector compatibility (UV, PDA, FLD, RID, ELSD, MS).
-
Gradient and isocratic operation modes for flexible method development.
-
Temperature-controlled column oven for reproducible separations.
-
User-friendly software for method validation and regulatory compliance (ICH, USP, FDA).
Benefits:
-
High precision and sensitivity for trace-level detection.
-
Reliable system performance for both routine QC and advanced R&D.
-
Suitable for multi-industry use in pharma, food, nutrition, biotech, and environmental labs.
Additional Information:
- Production Capacity: 20
- Delivery Time: 1-2 WEEK
- Packaging Details: PACKING CHARGES EXTRA ON ACTUAL BASIS
Budget Friendly Waters Manual HPLC (Refurbished)
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand Name | Waters |
| Model Name/Number | 515 pump with 2487 |
| Usage/Application | Laboratory Use |
| Flow Rate Range | 0.000 - 10.000 mL/min (standard heads) |
| Flow Precision and Accuracy Flow Precision | 0.1% RSD |
| Operating Pressure Maximum Operating Pressure | Up to 6000 psi (400 bar) |
| Wavelength Range | 190 - 700 nm |
Waters 515 HPLC Pump with 2487 UV Detector — Manual HPLC System
A reliable manual HPLC setup combining the Waters 515 Isocratic Pump with the Waters 2487 Dual Wavelength UV Detector, ideal for basic analytical applications and routine quality control.
This manual system features a Rheodyne manual injector and supports precise flow delivery for simple isocratic runs. The Waters 515 Pump delivers stable flow rates, while the 2487 UV Detector ensures sensitive detection of analytes with selectable dual wavelengths (190–600 nm).
Why Choose This Manual Waters HPLC System?
✔️ Cost-effective solution for basic testing
✔️ Ideal for routine QC, assay, and purity checks
✔️ Simple to operate, no software dependency
✔️ Trusted Waters build quality with dependable performance
Recommended for:
-
Pharma QC Labs
-
Educational Institutes
-
Small-Scale Manufacturing Units
-
R&D Labs needing manual HPLC setups
Additional Information:
- Packaging Details: packing charges as per actual basis
Low Investment HPLC System
Minimum Order Quantity: 1 Piece
Product Brochure
| Usage/Application | Laboratory Use |
| waters | Fast Data Rate Up to 20 Hz |
| shimadzu manual hplc | Flow Rate Range 0.001 to 10.000 mL/min |
| shimadu | Flow Rate Accuracy +-1% |
| Brand Name | shimadzu and agilent |
| Model Name/Number | waters and shimadzu manual hplc |
Waters and shimadzu Manual HPLC System
We proudly introduce refurbished Waters and Shimadzu Manual HPLC Systems – a cost-effective solution for laboratories seeking high accuracy and dependable performance without exceeding their budget.
🔧 System Highlights:-
🏷️ Refurbished & Fully Tested Waters / Shimadzu HPLC units
-
✋ Manual HPLC Systems – ideal for robust routine applications
-
🧪 Includes Pump, Manual Injector, Detector (UV/UV-VIS), Column Oven
-
🔄 Compatible with industry-standard columns & software
-
🛠️ Installation, basic training & support included
-
🧴 Delivered with starter kit: tubing, fittings, solvent bottles & consumables
-
Pharmaceutical QC / R&D
-
Academic research labs
-
Environmental & chemical analysis
-
Food & beverage testing
🚛 PAN India Delivery | 🔧 On-site Support Available
Cosmetic & Personal Care Industry HPLC
Minimum Order Quantity: 1 Piece
Product Brochure
| Flow Rate | 0.01 - 10 mL/min |
| Pump Type | Quaternary |
| Brand | Waters |
| Frequency Range | 190 - 800 nm |
| Detector | 2998 |
We offer refurbished Waters Alliance e2695 HPLC with 2998 PDA Detector, specially suited for the Cosmetic & Personal Care industry. This system provides accurate separation, identification, and quantification of active ingredients, preservatives, UV filters, antioxidants, and colorants used in cosmetic formulations.
✅ Applications in Cosmetic & Personal Care Industry
-
Analysis of preservatives (parabens, sorbates, benzoates)
-
Detection of UV filters in sunscreens (oxybenzone, avobenzone, octinoxate)
-
Quality testing of antioxidants (BHT, BHA, Vitamin E)
-
Measurement of fragrances, essential oils, and plant extracts
-
Stability testing and impurity profiling of cosmetic formulations
-
Analysis of synthetic & natural colorants in creams, lotions, and shampoos
✅ Key Features
-
Waters e2695 HPLC System with quaternary pump and autosampler
-
2998 PDA Detector for full spectral analysis (190–800 nm)
-
High precision, reproducibility, and compliance with international standards
-
Empower™ software compatible for data handling & reporting
-
Suitable for R&D, quality control, and regulatory compliance
Refurbished waters HPLC System for Starch hydrolysates and oligosaccharides
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand Name | Waters |
| Model Name/Number | e2695 with 2414 RI Detector |
| Usage/Application | Laboratory Use |
| Refractive Index Range | 1.00 to 1.75 RIU |
| Measurement Range | 5.0 × 10⁻⁴ to 7.0 × 10⁻⁹ RIU |
| Noise Level | ±1.5 × 10⁻⁹ RIU (in RIU mode) |
| Drift | 2.0 × 10⁻⁷ RIU/hr |
| Flow Rate Range | 0.1 to 10.0 mL/min |
| Sensitivity Settings (RIU mode) | 1.0 × 10⁻⁶ to 5.0 × 10⁻⁴ RIU |
| Filter Options | Digital Hamming or RC types, programmable filter time constant |
The Waters HPLC System, equipped with a 2414 Refractive Index Detector, is designed for accurate and reliable analysis of starch hydrolysates, sugars, and oligosaccharides. It provides precise quantification of glucose, maltose, maltotriose, and other carbohydrate components commonly found in food, beverage, and bioprocess samples.
This system ensures stable isocratic operation, excellent reproducibility, and high sensitivity for compounds that lack UV absorbance. With Waters’ proven engineering and performance, it is ideal for routine quality control and research applications requiring dependable carbohydrate analysis.
Key Features-
Accurate analysis of starch hydrolysates and oligosaccharides
-
Equipped with Waters 2414 RI Detector for non-UV active compounds
-
Consistent and stable baseline performance
-
Ideal for food, pharmaceutical, and biotechnology laboratories
-
Reliable and easy-to-use system for quantitative analysis
Additional Information:
- Packaging Details: Packing charges on Actual Basis
HPLC System for Chemical and Petrochemical Industry (Refurbished)
Minimum Order Quantity: 1 Piece
| Brand Name | Agilent |
| Model Name/Number | 1200 series HPLC |
| Usage/Application | Laboratory Use |
| Pump Module Flow rate range | 0.001 - 10.000 mL/min (Quaternary) |
| Pump Module Flow precision | < 0.07 percent RSD or < 0.02 min SD |
| Pump Module Pressure range | Up to 600 bar (8700 psi) |
| Pump Module Gradient capability | Binary or Quaternary low/high-pressure mixing |
| Pump Module Mixing accuracy | +-0.5% |
| Autosampler Module Injection range | 0.1 - 100 uL |
| Autosampler Sample capacity | 100 x 2 mL vials (standard) |
| Autosampler Module Injection precision | < 0.25 percent RSD |
| Column Compartment Temperature range | 10 DegreeC below ambient to 80 DegreeC |
| Stability | +-0.15 DegreeC |
| Capacity | Up to 3 columns (up to 30 cm length) |
Refurbished HPLC System for Chemical and Petrochemical Industry
Our refurbished High-Performance Liquid Chromatography (HPLC) system, such as the Agilent 1200 Series, is specifically configured to meet the analytical demands of the chemical and petrochemical industry. Carefully restored to OEM standards, this system provides reliable, high-precision performance for both routine quality control and advanced chemical analysis.
Industry Applications-
Raw material and solvent identification
-
Additive and stabilizer quantification in fuels, oils, and polymers
-
Impurity profiling and trace-level contaminant analysis
-
Monitoring of process intermediates and final products
-
Separation and quantification of surfactants, aromatics, aldehydes, and organic acids
-
Equipped with high-pressure binary or quaternary pumps for consistent and accurate solvent delivery
-
Diode Array Detector (DAD) or Variable Wavelength Detector (VWD) for multi-wavelength detection of complex compounds
-
Autosampler with high precision and low carryover for unattended operation
-
Thermostatted column compartment ensures stable and repeatable separations even in fluctuating lab environments
-
Integrated with Agilent ChemStation software for method development, data analysis, and regulatory documentation
-
Each unit undergoes complete internal cleaning, parts replacement, calibration, and performance testing
-
Validated with real samples from petrochemical applications to ensure accurate results
-
Delivered with standard IQ/OQ/PQ documentation (on request)
-
Cost-effective alternative to a new HPLC with no compromise on performance
-
Compatible with industry-standard methods such as ASTM, ISO, and BIS for petrochemical analysis
-
Backed by limited warranty and post-sale support (installation/training optional)
-
Petrochemical refineries
-
Polymer and plastic manufacturing labs
-
Specialty chemical production units
-
R&D and QA/QC labs in chemical industries
Agilent 1100/1200 HPLC System for Detection of herbicides, pesticides, and phenols
Minimum Order Quantity: 1 Piece
| Brand Name | Agilent |
| Model Name/Number | 1100/1200 |
| Usage/Application | Laboratory Use |
| Particle Size Range | 2 µm to 400 µm (depending on sensor) |
| Operating temperature (ambient) | 4 to 55 °C (for most modules) |
| Humidity | < 95 % non-condensing |
| Power / Voltage | 100-120 VAC ±10 % or 220-240 VAC ±10 % (wide-range) |
| Flow range / settable | 0.001 to 10 mL/min in 0.001 mL increments |
| Flow accuracy | ±1 % or 10 µL/min (whichever is greater) |
| Operating pressure range | 0 to ~20 MPa (0-200 bar) for many configurations |
| Pressure pulsation | < 2 % amplitude (typically < 1 %) |
| Gradient mixing / composition precision | < 0.2 % RSD for composition |
| Delay / system volume | ~800-1,100 µL (depending on back pressure) |
The Agilent 1100/1200 High-Performance Liquid Chromatography (HPLC) System is a reliable and high-precision analytical instrument designed for the qualitative and quantitative detection of herbicides, pesticides, and phenolic compounds in various environmental, agricultural, and food samples.
Built with a modular design, it offers flexibility with components such as a quaternary or binary pump, autosampler, column oven, and Diode Array Detector (DAD) for high sensitivity and accurate spectral data. The 1200 series features advanced gradient accuracy, low dispersion flow paths, and rapid data acquisition for improved resolution and speed in trace-level analysis.
This system ensures excellent baseline stability, reproducibility, and detection precision, making it ideal for routine monitoring of contaminants and organic pollutants in water, soil, and plant extracts. Its robust construction, user-friendly ChemStation software interface, and compatibility with modern analytical columns make it a preferred choice in environmental and food testing laboratories.
Key Highlights:
-
Accurate detection of herbicides, pesticides, and phenols
-
Modular design with high sensitivity Diode Array Detector
-
Gradient and isocratic operation for complex sample separation
-
Excellent reproducibility and low noise performance
-
Suitable for environmental, agricultural, and food analysis
-
Reliable, easy maintenance, and compatible with modern analytical software
Additional Information:
- Delivery Time: 1-10 DAYS
- Packaging Details: PACKING CHARGES EXTRA ON ACTUAL BASIS
Hplc Ferrule
Minimum Order Quantity: 1 Pack
Product Brochure
| Material | PVC |
| Brand | ELECTRONRECYCLING |
| Packet Contain | 4 ferrrule and as per requirement |
| Pressure Rating | 6000 psi |
| PART NO | ERT 001 |
HPLC ferrules are precision-made sealing components used in high-performance liquid chromatography (HPLC) systems. They provide a leak-free, secure connection between the tubing and the HPLC column or fitting. Manufactured from durable materials such as stainless steel, PEEK, or graphite, ferrules ensure high chemical resistance, pressure stability, and reliable performance. They are available in different sizes to match capillary or stainless-steel tubing, offering consistent flow and preventing sample loss or contamination.
✅ Features:
-
Leak-tight sealing for HPLC fittings
-
Compatible with stainless steel, PEEK, and fused silica tubing
-
High chemical resistance and pressure durability
-
Ensures accurate, reproducible chromatographic results
Refurbished Agilent 6890 GC System for Detect Harmful Impurities like DEG with Precision
| Ambient Operating Humidity | 15°C to 35°C |
| Flow Control | Electronic Pressure Control (EPC) for precise and stable flow |
| Temperature Programming | Up to 6 ramps; programmable rate, final temperature, and hold time |
| Detector Options | FID (Flame Ionization Detector), TCD (Thermal Conductivity Detector), ECD (Electron Capture Detector |
| Oven Temperature Range | Ambient +4°C to 450°C |
The Agilent 6890 Gas Chromatograph is a reliable and high-performance system designed for accurate detection of Diethylene Glycol (DEG), Ethylene Glycol (EG), and other harmful solvent impurities in pharmaceutical, food, and chemical samples.
This system is ideal for quality control and regulatory testing as per WHO, USFDA, and Indian Pharmacopoeia standards. Equipped with Electronic Pneumatics Control (EPC) and Flame Ionization Detector (FID), it ensures stable operation, superior sensitivity, and consistent results.
✅ Detects DEG, EG, Methanol, Ethanol, and other volatile impurities
✅ Suitable for pharma, chemical, food, and environmental labs
✅ Refurbished system with calibration and performance validation
✅ Easy to operate with Agilent ChemStation software
✅ Compatible with multiple detectors (FID, TCD, ECD, MS)
✅ Optional Headspace Sampler for VOC testing
Waters e2695 with 2414 RI Detector (Refurbished)
Minimum Order Quantity: 1 Piece
| Brand | Waters |
| Usage/Application | Laboratory Use |
| Refractive index range: | 1.00 to 1.75 RIU. |
| Measurement sensitivity / range | 5.0 × 10⁻⁴ RIU down to ~7.0 × 10⁻⁹ RIU in some modes. |
| Noise | for example ±1.5 × 10⁻⁹ RIU (2 s Hamming filter, 1 mL/min 100% H₂O) in one specification. |
| Drift | 2.0 × 10⁻⁷ RIU/hour. |
| Compatible flow rate range | 0.1 to 10.0 mL/min (in one listing). |
| Flow cell volume | 10 µL. |
| Flow cell pressure limit | ≤100 psi. |
Key specifications:
-
Solvent management: 1 to 4 solvents in the standard quaternary (low-pressure) mixing configuration.
-
Flow rate range: up to ~10.000 mL/min (some listings note flow ranges from ~0.01-10.000 mL/min) with increments of 0.001 mL/min in certain configurations.
-
Maximum operating pressure: for example ~5,000 psi (≈345 bar) in many configurations. Autosampler capacity: Up to ~120 vials (e.g., five carousels of 24 vials each in one configuration) and injection volumes from ~0.1 µL to up to ~1000-2000 µL in optional configurations.
-
Sample compartment temperature control: For example set point range 4 °C to 40 °C for the autosampler compartment.
-
Column compartment / heater: One listing mentions ambient+5 °C to 65 °C temperature range.
-
Physical dimensions: In one example 18″ W × 22.5″ D × 22.5″ H (45.7 × 57.1 × 57.1 cm) and weight ~100 lb (45.5 kg).
Key specifications:
-
Refractive index range: ~1.00 to 1.75 RIU.
-
Measurement sensitivity / range: e.g., ~5.0 × 10⁻⁴ RIU down to ~7.0 × 10⁻⁹ RIU in some modes.
-
Noise: for example ±1.5 × 10⁻⁹ RIU (2 s Hamming filter, 1 mL/min 100% H₂O) in one specification.
-
Drift: e.g., ~2.0 × 10⁻⁷ RIU/hour.
-
Compatible flow rate range: 0.1 to 10.0 mL/min (in one listing).
-
Flow cell volume: 10 µL.
-
Flow cell pressure limit: ≤100 psi.
-
Optical/wetted materials: fused quartz flow cell; wetted parts include 316 stainless steel, PTFE, PEEK, quartz.
-
Internal temperature control: e.g., internal oven range 30 to 55 °C (settable in 1 °C increments) and optional external column heater ambient to 150 °C.
-
Electrical specifications: 100 – 240 VAC, line frequency 50/60 Hz, power consumption ~145 VA nominal.
-
Physical/Environmental: Dimensions ~Width 34.3 cm × Height 20.8 cm × Depth 61.0 cm; Weight ~16.3 kg. Operating temperature range ~15-40 °C; humidity 20-80% non-condensing.
Additional Information:
- Delivery Time: 1-2 week
- Packaging Details: packing charges extra on actual basis.
Agilent 1100/1200 HPLC System for Detection of herbicides, pesticides, and phenols (Refurbished)
The Agilent 1100 / 1200 Series HPLC System is a high-performance, reliable, and versatile liquid chromatography platform designed for accurate detection and quantification of herbicides, pesticides, and phenolic compounds in environmental, food, and industrial samples.
This refurbished system delivers exceptional precision, reproducibility, and stability—ideal for laboratories performing pollutant, contaminant, and residue analysis. Equipped with UV/DAD detectors, quaternary or binary pump, autosampler, column oven, and ChemStation software, it ensures smooth operation and consistent analytical results.
Key Features:
-
Accurate and reproducible quantitative analysis
-
Wide detection range (190–950 nm) for phenolic and aromatic compounds
-
Gradient and isocratic operation for flexible method development
-
Temperature-controlled column compartment for stable separation
-
Fully refurbished, tested, and validated system with warranty and support
Applications:
-
Detection of herbicides, pesticides, and phenolic pollutants
-
Water, soil, and food safety testing
-
Environmental and agricultural residue monitoring
-
Research and quality control laboratories