- Home
- ยป
- Our Product Range
- »
- HPLC System
HPLC System
Refurbished Hplc System Waters
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand Name | Waters |
| Model Name/Number | 2695 |
| Usage/Application | Laboratory Use |
| Response Time | Selectable (0.1 to 4.0 seconds) |
| Bandpass | 8 nm |
| Wavelength Repeatability | +-0.1 nm |
| Wavelength Range | 190 - 700 nm |
Refurbished Agilent 1100 G1311A Quat Pump HPLC System
Minimum Order Quantity: 1 Unit
Product Brochure
| Brand Name | Agilent |
| Brand | Agilent |
| Model Name/Number | 1100 G1311A Quat Pump |
| Usage/Application | Laboratory Use |
| Weight | 100 lb |
| Frequency | 60 Hz |
| Voltage | 240 V |
| Compatible detectors | FID TCD ECD TID PID |
Waters Alliance 2695 HPLC system with Waters 2487 Dual Absorbance UV/Vis Detector (Refurbished)
Minimum Order Quantity: 1 Piece
Product Brochure
| Model Name/Number | Waters Alliance 2695 HPLC system |
| Usage/Application | Laboratory Use |
| Programmable flow rate range | 0.000 and 0.010 to 10.000 mL/min in 0.001 ml/min increments. |
| Solvent conditioning | Vacuum degas, Dual operating modes, four chambers |
| Vial sampler | 5 tray having 24 position of each. |
| Maximum Operating Pressure | 4000 psi |
This Waters HPLC 2695 system is an integrated solvent sample management platform. This integration of two traditional high-performance liquid chromatography (HPLC) components streamlines all critical separation functions. It provides quaternary solvent, high-performance solvent delivery, integral helium sparge for solvent conditioning, integral plunger seal-wash system, 120-vial capacity sample management system, liquid-crystal display and keyboard user interface.
Pump, Vial Sampler, Injector
Ø Typical operating pressure: 4000 psi
Ø Gradient capability : Quaternary
Ø Gradient Valve: installed
Ø Vial sampler : Having 5 tray and 24 position of each
Ø Injector Maximum injection volume: 100µl
Ø Sample compartment: Temperature range (5°C -25°C)
Column compartment
Ø Temperature range (Ambient -60°C)
Detector
Ø Dual λ absorbance
Ø Wavelength range: 190 to 700 nm.
Performance Parameter:
Pump: Flow Rate Accuracy
Flow Rate Consistency
Flow Rate Precision
Gradient Accuracy
Injector: Injector Accuracy, Injector Precision, Injector Linearity, Carry over Test
Detector: Detector Linearity, Wavelength Accuracy
Column Oven: Temperature Accuracy.
Additional Information:
- Delivery Time: Within a week
- Packaging Details: Proper & Suitable Packaging.
Waters 2424 Evaporative Light Scattering (ELS) Detector Refurbished
Minimum Order Quantity: 1 Piece
Product Brochure
| Optics: | Heated optics bench (constant 50 DegreeC) |
| Light source | Tungsten halogen polychromatic front mounted, pre-aligned, user installable |
| Detector | Photomultiplier tube |
| Scattering angle | 60 degrees |
| Wetted materials | 316 stainless-steel, aluminum, viton, PTFE, FEP, silicone rubber, polyethylene, polyurethane |
DESCRIPTION:
The 2424 Evaporative Light Scattering (ELS) Detector is a compact detector that controls temperatures in both the nebulization and evaporation stages, maintaining low-dispersion characteristics for dependable HPLC/ELS results.
Working Principle
The principle of evaporative light-scattering detectors (ELSD) is to nebulize the column effluent into droplets that are carried by a nebulizing gas in an evaporator (or drift) tube and then directed toward a light beam. The intensity signal is related to solute concentration in the eluent.
Optical Component Specification
Optics: Heated optics bench (constant 50 °C)
Light source: Tungsten halogen polychromatic front mounted, pre-aligned, user installable
Detector: Photomultiplier tube
Scattering angle: 60 degrees
Wetted materials: 316 stainless-steel, aluminum, viton, PTFE, FEP, silicone rubber, polyethylene, polyurethane
Additional Information:
- Delivery Time: Within a week
- Packaging Details: Proper & Suitable packaging
Waters e Alliance 2695 HPLC system with Waters 2489 UV/Vis Detector (Refurbished)
Minimum Order Quantity: 1 Piece
Product Brochure
| Flow Rate | 0.01 - 5ml/min |
| Pump Type | Binary |
| Make | Waters |
| Modle | e Alliance 2695 |
| Detector Type | Waters 2489 UV/Vis |
| Used for | Industrial & laboratories |
| Performance | Complies as per Laboratories standards |
DESCRIPTION:
The Waters e Alliance 2695 HPLC Separations Module can be used for in-vitro diagnostic testing to analyse many compounds, including diagnostic indicators and therapeutically monitored compounds. The Separations Module is an integrated solvent and sample management platform.
WORKING PRINCIPLE:
High Performance Liquid Chromatography (HPLC) is a process of separating components in a liquid mixture. A liquid sample is injected into a stream of solvent (mobile phase) flowing through a column packed with a separation medium (stationary phase).
Specification
Pump, Vial Sampler, Injector
Ø Typical operating pressure: 4000 psi
Ø Gradient capability : Quaternary
Ø Gradient Valve: installed
Ø Vial sampler : Having 5 tray and 24 position of each
Ø Injector Maximum injection volume: 100µl
Ø Sample compartment: Temperature range (5°C -25°C)
Column compartment
Ø Temperature range (Ambient -60°C)
Detector
Ø Dual λ absorbance
Ø Wavelength range: 190 to 700 nm
Performance Parameter:
Ø Pump: Flow Rate Accuracy, Flow Rate Consistency, Flow Rate Precision, Gradient Accuracy
Ø Injector: Injector Accuracy, Injector Precision, Injector Linearity, Carry over Test
Detector: Detector Linearity, Wavelength
Additional Information:
- Delivery Time: Within a week
- Packaging Details: Proper & Suitable packaging
Shimadzu LC 2010A-HT Liquid Chromaograph
Minimum Order Quantity: 1 Piece
Product Brochure
| Usage/Application | Laboratory Use |
| Automation Grade | Automatic |
| model no | LC-2010A HT HPLC |
| Spectral bandwidth | 8nm |
| Wavelength precision | 1 nm |
| Leak capacity | 800uL |
Old and Used HPLC
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand Name | Waters |
| Brand | Waters |
| Model Name/Number | 2695 |
| Usage/Application | Laboratory Use |
| Flow Rate Range: | 0.0001 to 10.000 mL/min (0.01 mL/min increments) |
| Flow Accuracy: | +-1% or +-10 uL/min |
| Flow Precision: | <0.075% RSD |
| Gradient Accuracy: | +-0.5% (full scale) |
| Spectral Resolution: | ~1.2 nm |
This refurbished Waters HPLC system is a reliable and high-precision chromatography solution, ideal for laboratories requiring accurate, consistent, and high-throughput analytical performance. Fully restored and tested by experts, this system includes an integrated autosampler, solvent delivery unit, column compartment, and a UV/Visible detector, providing a complete package for routine analysis as well as complex research applications.
Known for its robust engineering and long-term dependability, Waters HPLC systems are widely trusted in pharmaceutical quality control, academic research, food safety, and environmental testing. The autosampler ensures high injection accuracy with minimal carryover, while the detector delivers sharp, stable baselines and excellent sensitivity for a wide range of compounds.
This refurbished unit has undergone comprehensive servicing, including the replacement of all critical wear parts such as seals, lamps, and tubing. It has been thoroughly calibrated for flow rate accuracy, leak testing, pressure performance, and detector sensitivity to ensure smooth operation in any lab setting.
Compatible with industry-standard software for method control and data analysis, this system offers both ease of use and regulatory compliance readiness. It’s an ideal solution for labs looking for dependable performance and significant cost savings compared to new systems. Installation, training, and AMC options are available on request.
Additional Information:
- Delivery Time: 1 week
Shimadzu LC - 2030C Liquid Chromatograph refurbished
Minimum Order Quantity: 1 Piece
Product Brochure
| Model Name/Number | shimadzu prominence-i lc-2030. |
| Usage/Application | Laboratory Use |
| Display Inch | 7 inch |
| Capacity | 184 vial |
| Dimension | W410xH605xD500 mm |
| Volume | 1.5 ml |
| Weight | 63 kg |
| Voltage | 230 |
| Shape | rectangle |
| Material | metal and plastic |
| Light Source | Deuterium (D2) lamp |
| Color | Black and White |
HPLC Display 2695/2695/2690
Minimum Order Quantity: 1 Piece
| Flow Rate | 0.01 - 5ml/min |
| Pump Type | Binary |
| Frequency Range | 50 Hz |
| Country of Origin | Made in India |
| Pack Type | Box |
| Brand | Agilent |
Our Demo lab is located in Ghaziabad G-2, Durga industrial area, Sahibabad (near major mohit sharma rajendra nagar metro station)
Shimadzu VP Series SCL-10AVP HPLC System Refurbished
Minimum Order Quantity: 1 Unit
Product Brochure
| Brand | Shimadzu |
| Model Name/Number | SCL-10AVP |
| Usage/Application | Laboratory Use |
| Temperature Zone | 35 Degree C |
| Volume | 240 V |
| Material | Mild Steel |
Hplc Water Alliance Column Refurbished
Minimum Order Quantity: 1 Piece
Product Brochure
| Model Name/Number | Waters Alliance Column heater Module |
| Usage/Application | Laboratory Use |
| Display Inch | customized |
| Size | customized |
| Country of Origin | Made in India |
Agilent 1200 Series HPLC System (Refurbished)
Minimum Order Quantity: 1 Piece
Product Brochure
| Made by | Agilent Technologies |
| Model | 1200 Series |
| Detector | VWD |
| Used For | Industrial & Laboratories |
| Performance | Complies As per Laboratories Standards. |
It is often used in easy and reliable polymer characterization. Gel Permeation Chromatography (GPC), also referred to as Size Exclusion Chromatography (SEC), is the technique of choice to characterize polymers. Average molecular weights and molecular weight distributions are calculated based on the elution behavior in a size exclusion column set.
The Agilent 1200 Series instrumentation offers excellent retention time precision and molecular weight data for this application. The Agilent 1200 Series Gradient system is the ideal Multi- Solvent HPLC Gradient System, offering the most flexibility for your research. The modular system allows you to easily expand your analytical capabilities depending on your research needs.
Agilent 1200 Series pumps
· Flow precision: < 0.1% RSD or 0.02 min SD, whichever is greater, (typically < 0.065% RSD or 0.015 min SD, six replicates, isocratic mode from 1 bottle, based on retention time
· Pressure pulsation: < 2% amplitude, (typically < 1%) at 1 mL/min isopropanol, at all pressures > 1 MPa, (> 10 bar, 147 psi)
· Compressibility Compensation: User-selectable, based on mobile phase compressibility
· Recommended pH Range: 1.0 – 12.5 pH range; solvents with pH < 2.3 should not contain acids which attack stainless steel
Agilent 1200 Series Thermostatted column compartment
· Temperature range: 10 degrees below ambient to 80 °C (SL version: 10 degrees below ambient to 100 °C)
· Temperature stability: ± 0.15 °C (SL version: ± 0.05 °C)
· Temperature accuracy: ± 0.8 °C, with calibration ± 0.5 °C
· Column capacity: Three 30-cm columns (if the application requires more columns, a second column compartment can be added)
Agilent 1200 Series Auto Sampler
· Sample capacity: 100 x 2-mL vials in 1 tray, 40 x 2-mL vials in 1/2 tray, 15 x 6-mL vials in 1/2 tray Microvials (100 or 300 µL) with sleeves.
· Injection volume: 0.1 – 100 µL injection range, up to 1500 µL with multiple draw.
· Precision: Typically < 0.5% RSD from 5 – 100 µL, typically < 1% RSD from 1 – 5 µL.
Agilent 1200 Series UV Detector
· Light Source – Deuterium Lamp.
· Wavelength Range – 190 -600 nm.
· Flow Cell Pressure Limit – 4 MPa.
Additional Information:
- Delivery Time: Within week.
- Packaging Details: Proper & Suitable Packaging.
Shimadzu LC-2010C HT Liquid Chromatograph Refurbished
Minimum Order Quantity: 1 Piece
Product Brochure
| Model Name/Number | LC-2010C HT |
| Usage/Application | Industrial |
| Display Inch | 2.5 |
| Temperature Zone | (Ambient temperature -15 DegreeC) to 60 DegreeC |
| Capacity | Up to 4 solvents |
| Dimension | W 430 x D 520 x H 605 mm |
| Height | 605 mm |
| Noise | +- 0.25 x 10-5 AU (for response of 1 s, 250 nm, air cell) |
Waters Alliance 2695 HPLC System Refurbished
Minimum Order Quantity: 1 Unit
Product Brochure
| Brand | Waters Alliance |
| Model Name/Number | 2695 |
| Usage/Application | Laboratory Use |
| Weight | 100 lb |
| Frequency | 63 Hz |
| Country of Origin | Made in India |
Shimadzu LC 10 AT VP with SPD-10A VP UV-Vis Detector (Refurbished)
Minimum Order Quantity: 1 Piece
Product Brochure
| Automation Grade | Manual |
| Power Consumption | 220 |
| Usage/Application | college /university |
| BRAND | shimsdzu |
| Typical operating pressure | 5000 psi |
| Injector Loop | 20 micro Littre (Manual Injector) |
| Wavelength range | 190 to 600 nm |
| Light source | D2 lamp |
| Used for | Industrial & Laboratories |
DESCRIPTION:
WORKING PRINCIPLE:
High Performance Liquid Chromatography (HPLC) is a process of separating components in a liquid mixture. A liquid sample is injected into a stream of solvent (mobile phase) flowing through a column packed with a separation medium (stationary phase).
Specification
Ø Typical operating pressure: 5000 psi
Ø Injector Maximum injection volume: 20µl (Manual Injector)
Ø Wavelength range: 190 to 600 nm
Ø Light source: D2 lamp, W lamp
Ø Wavelength repeatability: 0.1 nm
Performance Parameter:
Ø Pump: Flow Rate Accuracy, Flow Rate Consistency,
Ø Injector: Injector Precision, Carry over Test
Ø Detector: Detector Linearity, Wavelength Accuracy
Additional Information:
- Delivery Time: Within a week
- Packaging Details: Proper & Suitable packaging
2489 UV/Visible (UV/Vis) Detector Refurbished
Minimum Order Quantity: 1 Piece
Product Brochure
| Automation Grade | Automatic |
| Usage/Application | Laboratory |
| BRAND | Waters |
| Shape | Rectangle |
| Display Type | Digital |
| Portable | No |
| Wavelength range | 190 to 700 nm |
| Bandwidth | 5 nm |
| Wavelength accuracy | 1 nm (via patented Erbium filter) |
| Measurement range | 0.0001 to 4.0000 AU |
| Sampling rate | Up to 80 points/s |
Agilent 1100 Series FLD Detector (Refurbished)
Minimum Order Quantity: 1 Piece
Product Brochure
| Type | Liquid |
| Wavelength Accuracy | 2 nm |
| Wavelength Repeatability | 0.2 nm |
| Data Acquisition Rate | Up to 10 Hz |
| Flow Cell Volume | 8 UL (standard); other options available |
| Noise Level | 5 x 10 POWER -6 |
Metrohm 716 DMS Titrino old and used
Product Brochure
| Resolution (mV) | 0.01 mV |
| Resolution (pH) | 0.001 pH |
| Range (pH) | -2.000 to 20.000 pH |
| Range (mV) | -2000 to + 2000 mV |
| Model Name / Number | Metrohm 716 DMS Titrino |
| Accuracy (mV) | 2000mV |