- Home
- ยป
- Our Product Range
- »
- Water Detector
Water Detector
2998 PDA DETECTOR Blue Refurbished
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand Name | Waters |
| Display Type | Digital |
| Model Name/Number | 2998 Photodiode Array (PDA) Detector |
| Brand | Waters |
| Material | ms |
Waters2998 Detector Refurbished.
Product Brochure
| Brand Name | Waters |
| Model Name/Number | Waters 2998 PDA |
| Height | 8.2 inch |
| Noise | 254 nm, 2 points/s, 1.0 s, 30 s segments, bandwidth 3.6 nm (3-pixel bunch) |
| Weight | 12.6 kg |
| Frequency | 50 / 60 Hz |
| Shape | Rectangle |
| Accuracy | 1nm |
| Light Source | Deuterium lamp |
| Power Input | 230 |
| Color | White |
The Waters 2998 PDA Detector is a high-performance Photodiode Array detector designed for precise and simultaneous multi-wavelength detection in HPLC applications. Ideal for pharmaceutical, environmental, chemical, and research labs, the 2998 offers superior spectral resolution, quantitative accuracy, and robust performance. This refurbished unit has been fully tested, calibrated, and certified to perform to original manufacturer standards.
Waters e2695 HPLC System with 2998 PDA detector (Blue) Refurbished
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand Name | Waters |
| Model Name/Number | Waters e2695 HPLC System Refurbished |
| Usage/Application | Laboratory Use |
| Display Inch | 5.5 |
| Temperature Zone | 4 to 40 DegreeC |
| Capacity | 120 Vials |
| Dimension | H 57.1 cm (22.5 inches), D 64.8 cm (25.5 inches), W 58.4 cm (23.0 inches) |
| Height | 57.1 cm (22.5 inches) |
| Noise | 65 dB |
| Volume | 0.1 to 100.0 |
| Weight | 59.1 kg 130.0 pounds |
| Width | 58.4 cm 23.0 inches with optional column heater |
| Frequency | 50 to 60 Hz |
| Voltage | 100 to 240 VAC |
| Accuracy | +-1% or 10 |
| Light Source | Deuterium arc lamp |
| Power Input | 950 VA maximum |
| Color | Blue |
| Bandwidth | 5 nm |
| Column heater | 20 to 65 C, in 1 C increments 5 C above ambient |
| Maximum operating pressure | 5000 psi |
| Wavelength accuracy | +-1 nm |
| Wavelength range | 190 to 700 nm |
| Column heater/cooler | Ambient minus 15 or 4 C |
| Flow Rate Range: | 0.0001 to 10.000 mL/min |
| Flow Precision: | <0.075% RSD or <10 uL/min |
| Gradient Range: | 0-100% (for any two solvents) |
| Maximum Pressure: | 6000 psi (414 bar) |
| Injection Range: | 0.1 to 100 uL (standard); up to 250 uL with optional loop |
Agilent GC 7890A WITH 5975 MSD (Refurbished)
Minimum Order Quantity: 1 Piece
Product Brochure
| Model Name/Number | 7890A with 5975C |
| Usage/Application | Laboratory Use |
| Frequency | 50/60 HERTZ |
| Voltage | 230 VOLTS |
| Model | 7890A |
| 5975 Series MSD | 120 (-10% / +5%) |
| Standard oven ramp | 3000 BTU/hour including GC/MSD interface |
The Agilent 7890A GC can accommodate up to two autoinjectors, identified as Front Injector and Back Injector. The sampling valves are simple mechanical devices that introduce a sample of fixed size into the carrier gas stream. Valves are most frequently used to sample gases or liquids in constantly flowing streams
shimadzu lc 8a liquid chromatography (Refurbished)
Minimum Order Quantity: 1 Piece
Product Brochure
| Model Name/Number | LC 8A |
| Usage/Application | Laboratory Use |
| Flow range | 0.1-150 |
| Range of constant pressure control | 10 -300 |
| Safety pressure limit | Upper and lower limit |
| Suction filter | 10 |
| Ambient temperature range | 10-35 DegreeC |
| Line filter | Double type 2 and 1 |
Waters 2424 Evaporative Light Scattering (ELS) Detector Refurbished
Minimum Order Quantity: 1 Piece
Product Brochure
| Optics | Heated optics bench (constant 50 DegreeC) |
| Scattering angle | 60 degrees |
| High-flow rate (standard with detector) | 300 to 3000 , (gas flow at 1.80 L/min at 25 psi) |
| Optional low-flow rate | 50 to 500 , (gas flow at 0.77 L/min at 25 psi) |
| Nebulizer heater power | 0% to 100% |
Waters Alliance HPLC
Minimum Order Quantity: 1 Piece
Product Brochure
| Brand Name | Waters |
| Model Name/Number | Waters 2695 |
| Usage/Application | Laboratory Use |
| Light Source | Deuterium lamp |
| Wavelength Accuracy | +-1 nm |
| Wavelength Repeatability | +-0.1 nm |
Additional Information:
- Delivery Time: 1 week
Waters 2475 Fluorescence detector refurbished
Minimum Order Quantity: 1 Piece
Product Brochure
| Model Name/Number | 2475 |
| Usage/Application | Laboratory Use |
| Shape | RECTANGLE |
| Excitation wavelength range | 200 to 890 nm |
| Emission wavelength range | 210 to 900 nm |
| Bandwidth | 20 nm |
| Wavelength repeatability | +-0.25 nm |
| Pressure limit | 145 psi (10 bar) |
Waters 2996 PDA Detector Refurbished
Minimum Order Quantity: 1 Piece
Product Brochure
| Display Type | Analog |
| Measurement Range | 190-800 |
| Model Name/Number | Waters HPLC 2996 PDA Detector |
| Usage/Application | Industrial |
| Width | Width: 11.5 in. (29 cm) |
Additional Information:
- Item Code: 021
- Production Capacity: Width: 11.5 in. (29 cm) Depth: 24 in. (61 cm) Height: 8.5 in. (22 cm)
- Delivery Time: 1-2 Business Days
- Packaging Details: Packaging are Wrapped with white foam and Sealed with bubble wrapping, outer covering with Weather proofing And Sealed.
Waters 2487 Dual Wavelength Absorbance Detector Refurbished
Minimum Order Quantity: 1 Piece
Product Brochure
| Display Type | Digital |
| Measurement Range | wavelengths 370nm and greater |
| Model Name/Number | Waters 2487 Detector |
| Material | ms |
| Power Supply | 120V Power Cord |
Agilent G1888 Network Headspace Sampler
Minimum Order Quantity: 1 Piece
Product Brochure
| Model Name/Number | G-188 |
| Brand | AGILENT |
| Usage/Application | LABORATORY |
| sample tray | 70 |
| positions | 12 |
| Controlled T | 40 DegreeC to 240 DegreeC |
| Coupling with an inert | 7890A or 6890N |